fire brigade equipment from Pyramid Fire Protection, Sheffield South Yorkshire UK fire brigade equipment

fire brigade equipment from Pyramid Fire Protection, Sheffield South Yorkshire UK fire brigade equipment from Pyramid Fire Protection, Sheffield South Yorkshire UK
fire brigade equipment from Pyramid Fire Protection, Sheffield South Yorkshire UK Pyramid logo

 

fire brigade equipment

 

Dry and wet rising mains are intended for use by the Fire Brigade or properly trained personnel, to enable the rapid deployment of water to help fight fire in a building. Dry risers are 'uncharged' rising mains with outlet valves on each floor (typically located in convenient positions, like stair-case enclosures, for example) and an inlet valve external to and/or beneath the ground floor, so that the Fire Brigade can readily connect into the water supply. A wet riser is permanently charged with water.

Dry and wet risers, as well as underground hydrants and hose reels, require regular inspection and occasional maintenance to ensure that they will work in an emergency. Since 1989, it has been the responsibility of a building's owner / occupier to keep its hydrant systems in working order. We provide the full range of all the genuine and fully compliant and conformant brigade equipment you will need to service dry rising mains.

This range includes:

  • inlet breechings
  • inlet and outlet cabinets
  • outlet valves
  • standpipes, bars and keys.

Our range of inlet and outlet cabinets built to comply with BS5041: Part 5.

  • Designed to house inlet breechings and landing valves
  • Georgian wired glass panel and spring cylinder lock with key
  • Manufactured from zintec, epoxy polyester powder coated - Red
  • 2 way vertical       395mm wide x 595mm long x 295mm deep
  • 2 way horizontal   595mm wide x 395mm long x 295mm deep
  • Outlet                   463mm wide x 612mm long x 325mm deep
   

 

dry riser inlet breechings

Dry riser inlet breechings to BS5041 Part 3 are normally fitted in glass fronted cabinets on the outside walls of buildings and have either 2 or 4 inlet connections. For special requirements, a single inlet breeching is
available.

They are used to feed water into the rising main through 21/2" fire hoses. A 100mm (4") rising main uses a two-way inlet breeching and a 150mm (6") main uses a four-way inlet breeching.

Drain Valves to BS 5154 Normally fitted to inlet breechings but can be supplied separately.

Two-way Inlet Breechings 4" BSTD, 4" BSP parallel female or 100mm NP16 - can be mounted either horizontally or vertically.

Four-way Inlet Breechings 6" BSTD or flanged FLG-NP16.

 

 

Outlet Landing valves used on dry rising mains should normally be of the gate valve type, but globe pattern valves are occasionally used. They act as outlets from the rising main and are fitted in easily accessible positions on
each floor of a building above the first floor and sometimes in deep basement areas.

Dry Riser Gate Valves with 2.5" instantaneous female outlet to BS336, blank cap and chain, strap and padlock.Dry riser gate valves comply with the requirements of BS5041: Part 2. Valves can be mounted in boxes
complying with BS5041: Part 4.

  • Inlet flanged 2.5" BSP or 3" BS Table D or 65mm BS4504 Table 16/21
  • Inlet screwed 2.5" BSP
  • Aluminium alloy (unvalved) 2.5" dividing breech
  • Blank plugs in plastic, alloy, gunmetal and ruber

 

valves
BIB
valves
Horizontal

 

layflat hose

hose coupling

     

Type 1 and type 2 layflat hose
General purpose synthetic delivery hose. Suitable for industrial and rural fire brigades as well as static building protection. General industrial, commercial and civil engineering applications including water
authorities where a high burst performance hose is not necessary.

 

Lightweight and flexible
Heat and cold resistant
Anti rot and anti-twist
Type 2 version has a dirt repellant, external elastomeric coating

A separate range of high performance layflat hose is also available (Typically in red), ask for details.

branch pipesBranchpipes provide an adjustable nozzle to allow the curtain of water to be altered from a narrow spray to a wide spray. Nozzles provide a fixed jet of water. The basic branchpipe according to BS336 has an 2.5" inlet male instantaneous and outlet threaded 11/3" BSP male for either a plain jet or a branchpipe adjustable nozzle.
The branchpipe is controlled from SHUT-OFF through JET and SPRAY to wide angle CURTAIN by rotating the annular sleeve.

 